Manual settings like adjusting the DMX starting address are no longer needed. This is especially useful when the device is installed in a remote area.
RDM is integrated in the DMX-protocol without influencing the connections. The RDM-data is transmitted via the standard XLR-line – new DMX-cables are not necessary. RDM ready and conventional DMX devices can be operated in one DMX line. The RDM protocol sends own packages in the DMX512 data feed and does not influence conventional devices.
If DMX splitters are used and RDM control is to be used, these splitters must support RDM.
RDM controller with TFT touchscreen
- RDM controller for monitoring and remote control of DMX fixtures compliant with RDM (Remote Device Management)
- Quick analysis and configuration of fixture parameters, i.e. DMX start address, DMX mode, lamp hour count, fixture status
- TFT touchscreen for menu settings
- Various basic DMX control features integrated
- 1 DMX universe
- USB port for firmware updates
- 3-pin XLR connectors
- Power supply via included PSU
- Made in Europe
Power supply: | 230 V AC, 50 Hz |
via 12 V DC, 1 A power unit included in the delivery | |
Power consumption: | 12 W |
Number of control channels: | 512 |
DMX512/RDM connectors: | 3-pin XLR |
USB port: | 2.0, type B |
Dimensions (LxHxD): | 230 x 133 x 60 mm |
Rack installation | |
Minimum mounting depth: | 60 mm |
Weight: | 1 kg |